YOV SSG Vent Window PROJECT OUT w/ VENT MULTIPOINT LOCK 1. SIZE LIMITATIONS: (Based on AW-70 & AW-100 Designation) VENT WIDTH A B HP SNUBBERS - H-1901 (AW-100) SNUBBERS - E3-1103 (AW-70) 3 SNUBBERS (2 AT 1/4 POINTS, 1 ON CENTER) 2 SNUBBERS * Indicates size as tested (2 AT 1/4 POINTS) 1 SNUBBER (1 ON CENTER) B 48 " 50 " APPROVED SIZES 36 " 38 " C TESTED SIZE D 24 " 15-3/4 " A 24 " 21-1/16 " Max 36 " 48 " 21-1/16 " Max VENT WIDTH 60 " 62 " 21-1/16 " Max VENT LOCK POINTS (Min Width = 21-1/2 " ) 72 " 74 " LOCK POINT SNUBBER * C D VENT HEIGHT MINIMUM SIZE 2.4 sq. ft. 21-1/2 " [546.1mm] 15-3/4 " [400.0mm] 41 " [1041.4mm] 50 " [1270.0mm] MAXIMUM SIZE 16.4 sq. ft. (Based on 70 psf and listed hardware) 62 " [1574.8mm] 38 " [965.2mm] 74 " [1879.6mm] 31 " [787.4mm] 2. FLORIDA PRODUCT APPROVED *NON-IMPACT* Page-46 05-1018-08 | Effective Date: May 30, 2023 VENT HEIGHT 11 " Max. (AW-100 Only) 21-1/2 " 11 " Max. (AW-100 Only)