YSD 600 T/TH Sliding Door SLIDING DOOR SIZE LIMITATIONS (NON-IMPACT, Continued) CONFIGURATION Without Reinforcing Design Load +75/-75 PSF OOXO & OXOO With Reinforcing Design Load +90/-90 PSF 16'-3 " x 9'-0 " MAXIMUM FRAME SIZE* (AS TESTED) 20'-6 " x 8'-0 " Without Reinforcing Design Load +75/-75 PSF Without Reinforcing Design Load +100/-100 PSF O FIXED OXXO X X O FIXED With Reinforcing Design Load +120/-120 PSF With Reinforcing Design Load +90/-90 PSF Without Reinforcing Design Load +75/-75 PSF XOOX With Reinforcing Design Load +90/-90 PSF All doors with frame heights over 96 " must be reviewed by YKK AP Engineering. * If the height to width ratio exceeds 3:1, the sliding door must be reviewed by YKK AP engineering. O FIXED NOTE: Frame width and height should allow 3/4 " for width & 1/2 " for height overall clearance between the door frame and rough opening. This allows for thermal expansion and ease of installation. Page-26 FRAME WIDTH 3/8 " ROUGH OPENING 06-1001-10 | Effective Date: Nov 12, 2021 3/8 " FLOOR ELEV. X 20'-6 " x 8'-0 " 16'-3 " x 8'-0 " 16'-3 " x 8'-0 " 16'-3 " x 9'-0 " 20'-6 " x 8'-0 " 16'-3 " x 9'-0 " FRAME HEIGHT 1/8 " ROUGH OPENING 3/8 "