TROUGH TRAY Use these cable fill tables to determine the tray size(s) needed for your installation. DATA CABLE FILL TABLE TRAY 50/50 (2x2) 50/100 (2x4) 50/200 (2x8) 50/300 (2x12) 100/100 (4x4) 100/200 (4x8) 100/300 (4x12) 100/500 (4x20) 100/600 (4x24) Plenum (.17 " ) 88 Cat 5e 4-pr 177 355 532 351 703 1055 1758 2110 MAX NUMBER OF CABLES PER CODE Cat 5e 4-pr Non-Plenum (.19 " ) 71 142 284 426 281 563 844 1407 1689 Plenum (.22 " ) 53 Cat 6e 4-pr 106 212 318 209 419 629 1049 1259 Plenum (.35 " ) 20 41 83 Cat 6a 4-pr 125 82 165 248 414 497 MC POWER CABLE FILL TABLE MAX NUMBER OF CABLES PER CODE 2C (12 AWG) THHN TypeMC AlumArmor 11 23 47 71 23 47 71 119 143 3C (12 AWG) THHN TypeMC AlumArmor 10 21 42 63 21 42 63 105 126 CABLE CAPACITY (BASED ON 40% FILL*) TROUGH TRAY SERIES TRAY SIZE (HxW-IN) CABLE FILL AREA (IN2 CABLE TYPE† 50/50 50/100 50/200 50/300 100/100 100/200 100/300 100/500 100/600 2x2 2x4 ) AREA Fiber - 0.063 " (1.6mm) 0.003 Fiber - 0.079 " (2.0mm) 0.005 Fiber - 0.118 " (3.0mm) 0.011 Ribbon - 0.205 " (5.2mm) 0.033 Category 5E - 0.17 " (4.32mm) 0.023 Category 6- 0.24 " (6.1mm) 0.045 Category 6A - 0.30 " (7.6mm) 0.071 497 316 141 46 68 34 21 994 632 283 93 136 68 43 1988 1264 566 187 273 137 87 3.875 7.75 2x8 15.5 2x12 23.25 4x4 15.5 1988 1264 566 187 273 137 87 4x8 31 NUMBER OF CABLES 2983 1897 850 281 409 205 131 †Typical cable diameters - for exact results, use the installed cable diameter provided by manufacturer) 3977 2529 1133 375 546 274 175 4x12 46.5 5966 3794 1700 563 819 411 263 4x20 77.5 9944 6324 2834 939 1365 685 438 4x24 93 11933 7589 3401 1127 1638 822 526 * 40% fill represents the maximum number of cables that can be practically installed (tray is piled to top of siderails with cable due to cable straightness and gaps between cables). Tray dimensions are nominal. C.7 WWW.LEGRAND.US/CABLOFIL TROUGH TRAYhttp://WWW.LEGRAND.US/CABLOFIL