WIREMOLD / OPEN SPACE RATCHET-PRO™ SERIES FLOOR BOXES Ratchet-Pro RPNFB, RPSFB and RPSFB-OG Series Floor Box Kits Ordering Information 2HUB 2 " Conduit Transition Hub 125CRR Conduit Reducing Ring Trade size 2 " die cast zinc conduit fitting allows for 2 " conduit to transition into a shallow box design. Includes: die cast fitting gasket. Accepts standard 2 " threaded conduit or trade size EMT and PVC conduit fittings. NOTE: For use with RPSFB and RFSFB-OG Series floor boxes. RP-DIV Divider Used to isolate power and low voltage (communications and audio/video) compartments. Graduated markings indicating location to cut divider to, in order to match concrete pour. Conduit reducing ring allows for 1 1/4 " conduit hub (for RPNFB only) to allow for smaller conduit feeds where needed. Ring includes: (2) blanking plug, (2) 3/4 " trade size plugs and (2) 1 " trade size plugs. 2CRR Conduit Reducing Ring Conduit reducing ring allows for 2 " conduit hub (for RPNFB only) to allow for smaller conduit feeds where needed. Ring includes: (2) blanking plug, (2) 1 1/2 " trade size plugs and (2) 1 1/4 " trade size plugs and (2) blank plugs. 1CRR Conduit Reducing Ring Conduit reducing ring allows for 1 " conduit hub to accept smaller conduit feeds where needed. Ring includes: two (2) blanking plugs, (2) 3/4 " trade size plugs, and (2) 1/2 " trade size plugs. Wire Fill Calculations for RPSFB & RPSFB-OG Floor Boxes MINIMUM BOX HEIGHT (Measured inside from top of cut box - disregard excess height) 3 1/2 " 4 " 4 1/2 " 5 " 5 1/2 " 6 " 89mm 102mm 114mm 127mm 140mm 152mm Volume - Cat. No. RPSFB (Each Gang) 55 cu.in. 60 cu.in. 65 cu.in. 70 cu.in. 75 cu.in. 80 cu.in. 901 ml. 983 ml. 1065 ml. 1147 ml. 1229 ml. 1311 ml. RP7CTC & RP4FFCTC (Available Volume for Conductor Calculations) 918 ml. RPAV3CTC & RP4CTC (Available Volume for Conductor Calculations) Not recommended for pours less than 4 " [102mm] 56 cu.in. 61 cu.in. 66 cu.in. 71 cu.in. 76 cu.in. 1000 ml. 1082 ml. 1164 ml. 1246 ml. Wire Fill Calculations for RPNFB Floor Boxes MINIMUM BOX HEIGHT (Measured inside from top of cut box - disregard excess height) 3 1/2 " 4 " 4 1/2 " 5 " 5 1/2 " 6 " 89mm 102mm 114mm 127mm 140mm 152mm Volume - Cat. No. RPNFB (Each Gang) 35 cu.in. 40 cu.in. 45 cu.in. 50 cu.in. 55 cu.in. 60 cu.in. 574 ml. 656 ml. 738 ml. 820 ml. 901 ml. 983 ml. RP7CTC & RP4FFCTC (Available Volume for Conductor Calculations) 41 cu.in. 46 cu.in. 51 cu.in. 56 cu.in. 590 ml. 672 ml. 754 ml. 836 ml. 918 ml. RPAV3CTC & RP4CTC (Available Volume for Conductor Calculations) Not recommended for pours less than 4 " [102mm] 36 cu.in. 25 cu.in. 30 cu.in. 35 cu.in. 40 cu.in. 45 cu.in. 410 ml. 492 ml. 574 ml. 656 ml. 738 ml. For single service activations - RPAMD4CTC, RPAMD8CTC and RP9AM2CTC, combine both gangs to determine available wire fill. 70 WWW.LEGRAND.US/WIREMOLD 45 cu.in. 50 cu.in. 55 cu.in. 60 cu.in. 65 cu.in. 738 ml. 820 ml. 901 ml. 983 ml. 1065 ml. FLOOR BOXEShttp://WWW.LEGRAND.US/WIREMOLD