PW LADDER TRAY OHCB A OVERHEAD CLAMP KIT * Designed for trapeze hanging of Itray without drilling. * Mounting kits available for 3/8" and ½" threaded rod * Kit includes: eight SFHN (nuts with washers), two top brackets, two bottom brackets. Threaded rod sold separately. * Load rated at 1220 lbs/pair * Can be used on fittings or straight sections of PW Itray PRODUCT CODE OCK OBCB38KIT .375 1.5 3.6 3 OBCB12KIT .5 1.5 3.6 3 FWPS A OUTDOOR CONVERSION KIT LENGTH LENGTH (TOP) (BOTTOM) HOLE SIZE WIDTH FIRE WALL PENETRATION SLEEVE Makes ladder tray wall penetrations weather resistant to minimize water intrusions. Removable cover/shield fastens to tray and wall penetration sleeve for the utmost in weather protection. PRODUCT FASTENER OPTIONS CODE OCK FASTENERS ZN M G 20" Loose collar slides over sleeve after it is placed in the wall PRODUCT CODE FASTENER OPTIONS FWPS GE S6 Fixed collar is welded to sleeve Cable trays are attached to both ends of the sleeve using standard splice plate connectors CATALOG NUMBERING EXAMPLE: 7/16" diameter holes W*+6" for 3/8" hardware H / Material W Fasteners (not included) 4G - FWPS -06-S6 GE S6 H*+6" * Steel only; aluminum not available as it does not meet W*=Nominal Tray Width fire rating requirements H*=Tray Side Rail Height * See pgs. B.58-59 for more information CATALOG NUMBERING EXAMPLE: H / Material W Fasteners 4A - OCK -06-S6 * Wall Penetration Sleeve (WPS or FWPS) not included in kit, must be ordered separately Hilti Fire Blocks SIDE VIEW Wall Assembly (Gypsum 20" Wall Shown) Loose Cables collar slides over sleeve after it is placed in the wall AdjustableCollar Hilti Fire Blocks Penetration Sleeve Fixed Collar Floor Assembly Cables WPS WALL PENETRATION SLEEVE M G 20" Fixed Fixed Collar collar is welded to sleeve Loose collar slides over sleeve after it is placed in the wall Provides a rigid support for cable tray at wall penetrations. Overall length of the sleeve is 20". Will fit walls up to 8" thick. Bonding jumpers are not required for use with wall sleeves. Two pairs of splice plates and fasteners are included for tray attachment. Fixed collar is welded to sleeve Cable trays are attached to both ends of the sleeve using standard splice plate connectors END VIEW Cable trays are attached to both ends of the sleeve using standard splice plate connectors W*+6" 7/16" diameter holes for 3/8" hardware (not included) W*+6" Masonry Anchors (Not Included) Adjustable Collar Wall Anchors (Not Included) Penetration Sleeve 7/16" diameter holes for 3/8" hardware (not included) H*+6" H*+6" Wall Assembly (Gypsum Wall Shown) Hilti Fire Blocks FASTENER OPTIONS WPS GE S6 W*=Nominal Tray Width H*=Tray Side Rail Height Each cable tray firestop sleeve includes: * One penetration sleeve with flanges * Hilti Fire Blocks * One Hilti Firestop Putty Stick Hilti Fire Blocks * Hardware for cable tray connection to the wall sleeve CATALOG NUMBERING EXAMPLE: Hilti Fire Blocks H / Material W Fasteners AdjustableCollar 4M - WPS -06-S6 Cables Wall Assembly (Gypsum Wall Shown) Fixed Collar Penetration Sleeve Floor Assembly Cables Hilti Fire Blocks Fixed Collar Wall Anchors (Not Included) Adjustable Collar Masonry Anchors (Not Included) Cables Penetration Sleeve UL classified for use with: Cables 2-hr concrete or block walls Penetration Sleeve 2-hr concrete floors 1-hr gypsum walls 2-hr gypsum walls AdjustableCollar Fixed Collar ITRAY - ACCESSORIES W*=Nominal Tray Width H*=Tray Side Rail Height PRODUCT CODE Floor Assembly B.31 Fixed Collar For detailed material and finish descriptions, see page B.6. Wall Anchors (Not Included) Adjustable Collar Masonry Anchors (Not Included) WWW.LEGRAND.US/CABLOFIL Penetration Sleevehttp://WWW.LEGRAND.US/CABLOFIL