W*=Nominal Tray Width W*=Nominal H*=Tray Side Rail HeightTray Width H*=Tray Side Rail Height PW LADDER TRAY Floor Firestop Sleeve Example 0440 product used as a floor sleeve per UL assembly F-A-3022 Floor Firestop Sleeve Example 0440 product used as a floor sleeve per UL assembly W-L-3226 and C-AJ-3232 Hilti Fire Blocks Hilti Fire Blocks Wall Assembly WallShown) Assembly (Gypsum Wall (Gypsum Wall Shown) Hilti Fire Blocks Hilti Fire Blocks Cables Cables AdjustableCollar AdjustableCollar Cables Fixed Collar Fixed Collar Penetration Sleeve Penetration Sleeve Floor Assembly Floor Assembly Cables Fixed Collar Fixed Collar Masonry Anchors Masonry Anchors (Not Included) (Not Included) Adjustable Collar Adjustable Collar Wall Anchors Wall Anchors (Not Included) (Not Included) Penetration Sleeve Penetration Sleeve WALL/FLOOR SLEEVE DESCRIPTION Designed for single runs of cable tray, having a height and width to match the tray system specified. One end of the 20 inch sleeve has a flange attached 6 inches from the end, while the flange for the other end is "floating" and is free to slide directly against the face of the wall as needed. The 20 inch length of the sleeve will accommodate a wall thickness of up to 8 inches. A wall thickness of 8 inches will result in the sleeve protruding 6 inches from each side of the wall. Both ends of the sleeve are punched with holes for attaching cable tray splice plates or hardware needed for the tray system specified. TECHNICAL DATA INSTALLATION The opening in the wall should be within 1 inch of the nominal height and width of the cable tray. The flanges of the sleeve have 7/16" diameter mounting holes for attachment to the wall using 3/8" diameter hardware. Hardware for wall attachment is not included. After the sleeve is mounted in the wall or floor, the cable trays on either side of the sleeve can be connected using the hardware supplied with the sleeve. When the trays are in place, the cables should be pulled through the wall and sleeve as needed. After all of the cables are installed in the tray, install the Fire Blocks as described. Any voids between cables should be filled with the Firestop Putty Stick. HILTI FIRE BLOCKS INSTALLATION Walls: Hilti Fire Blocks shall be installed with 5" dimension projecting through and centered within wall assembly. Floors: Hilti Fire Blocks shall be installed with 5" dimension projecting through opening, flush with the top surface of sleeve or recessed within sleeve at any level above the top surface of floor. Construction ............ Arc Welded Sleeve Dimensions .............. 20" x Tray Width x Tray Height Flange Dimensions .............. (Tray Width + 6") x (Tray Height + 6") UL Classification ...... Qualifies for use as an equipment grounding conductor per N.E.C. 392.7. Cross-sectional area and amperage ratings are based on the cable tray system attached to the sleeve. Fire blocks fill the annular space between the cables and the sleeve. Fire Blocks may be cut to match the profile of cables or to fit opening. Any voids should be filled with 0618 Firestop Putty Stick. CONNECTOR SYSTEM NO. PRODUCT NO. 6M2- 0 4 4 0 - 3 6 - G E SIDE RAIL HEIGHT 4 - 4" 5 - 5" 6 - 6" 7 - 7" For detailed material and finish descriptions, see page B.6. WIDTH FITTING SERIES MATERIAL M G T This item must be specified as SERIES 2 06 - 6" 09 - 9" 12 - 12" 18 - 18" 24 - 24" 30 - 30" 36 - 36" FASTENER OPTIONS GE S6 WWW.LEGRAND.US/CABLOFIL METALLIC FIRESTOP SYSTEMS WALL PENETRATION SLEEVE CATALOG NUMBERING EXAMPLE: B.69http://WWW.LEGRAND.US/CABLOFIL