Tension Controls VERSATEC® Dancer Control Mode DISPLAYS OUTPUT AND PRESENT DIAMETER SETUP NUMBER OPERATING MODE TENSION ON/OFF HOME MENU-DRIVEN OPERATION MANUAL/ AUTOMATIC MODE TACTILE FEEDBACK KEYPAD DATA INPUT Push Button Setup and Operation Operation & Alphanumeric Display Menu driven operation and setup with online help System Status Home screen displays output, diameter (when US-2 sensor is used), setup number, and operating mode simultaneously System Status Home screen displays output, setup number and operating mode simultaneously (without diameter sensor) Select Control Method Optimized method for control of brake, clutch or drive in torque mode Select Control Method Optimized method for control of drive in speed mode Added Stopping Torque Helps stop unwind rolls with additional torque at machine stop 18 Tension Controls Push Button Tuning Two-step dynamic tuning of system response Direct Data Access Results of dynamic tuning can be accessed and recorded Direct Data Input Parameters can be accessed and input directly Select Language Choose English, French, German, Italian or Spanish Select Units Choose English or metric units Control Dancer Loading Tension Output sets Dancer loading for remote adjustment Use US-2 Ultrasonic Sensor Improves stability with large roll ratios, allows rewind taper and full roll and core detection Push Button Data Entry Input minimum and maximum diameter and distance to axis Adjustable Taper Tension Input desired rewind taper when using Tension Output and diameter sensor Core and Full Roll Detect Core and full roll alarms flash on the display and trip external indicators when diameter sensor is used