Thermal
LCP DX Cooling, the System Solution for
Smaller Data Centers
Even if a data center consists of just one room with one
server enclosure, the highpower dissipation of computer
hardware can quickly lead
to a dangerous build-up of
heat. In fact, studies show that
smaller data centers tend to
be installed in locations that
are even more confined than their larger counter parts, further
increasing the risk of temperature-related failure. If the so-called
“comfort temperature” of the server is not met, shortened service
lives or total failure are real threats.
In major data centers, climate control is routine, but in small
companies with more limited resources, the servers, switches
and storage systems may be less than completely protected. If
the devices are housed in a 19 inch enclosure, air is usually only
circulated by a fan in the ceiling plate or a 19 inch rack-mounted
fan. If the devices are standing around openly in the room, there
may be no climate control or only a less than inefficient room air
conditioning system.
The Rittal Liquid Cooling Package Direct (LCP DX) is designed to
address this situation. This flexible climate control option for use
in small and medium enterprises can dissipate heat losses of up
to 12 kW through an integrated cooling unit, and two versions are
suitable for rack-based and row-based climate control.
The LCP DX fits into environments where small or mediumsized IT installations need to be cooled and where climate control
with air/water heat exchangers or cold water would be too costly.
The DX system includes an integrated, speed-controlled compressor, an electronic expansion valve and related refrigeration components that include an appropriate external condenser mounted
outside the data center. No active control components are required to operate the external condenser, fan speed is determined
only by the pressure of the refrigerant.
The LCP DX is available in two versions. The laterally mounted
LCP Rack DX, moves cold air either to the right or to the left in a
19 inche rack. With series cooling, the LCP Inline DX is mounted
between individual racks and blows the cool air from the front
into the cold aisle. Each version is quick and easy to install because
of its compact and largely pre-assembled design.
New Option for Thermoelectrically Cooled
Electronic Enclosures Makes Wash Downs Easy
EIC Solutions, Inc. has introduced the
new M74 clean out modification option that
facilitates wash down of thermoelectric coolers mounted to electronic enclosures. The
M74 option was application-driven arising
from suggestions received from customers in
food processing, and other process industries requiring frequent rinsing or washing of
equipment. By making washdown faster and
easier, the clean out modification helps minimize downtime and helps promote consistent production rates.
Electrical wires and electronic gear used
in wash down processes are enclosed to protect them from liquids
and cleaning agents. The enclosures are then subject to wash
down regulations. During both manufacturing and wash down
20
procedures, liquid and debris may find their way into the openings in the thermoelectric air conditioner covers. The openings
are machined into the cooler panels to create space for fans and
to permit adequate air circulation. A thorough wash down may or
may completely not flush out the openings.
Removing the air conditioner covers used to require the use
of screwdrivers, wrenches or other tools. Additionally, hardwired
electrical connections to fans had to be cut which took time
and made for tedious reinstallation of the covers. EIC’s clean out
modification option eliminates the need for tools when removing
the covers for cleaning. This simplifies and expedites wash down
procedures and also speeds up the process of reinstalling the covers which means less production downtime.
The internal portion of the air conditioner’s “hot-side” may
then be power washed assuring the removal of clinging debris. A
more thorough cleaning is achieved through removal of the fans,
which are rated for moisture resistance and are not adversely affected by wash downs.
Fujipoly Thermal Gel Sheets are a Cooling
Influence on LED Lighting
Over the last several years
hundreds of major electronics
manufacturers have expanded their
use of LED lighting to enhance both
product appearance and functionality. Recent design trends have
integrated LED lighting packages in
thousands of consumer and industrial electronic platforms.
One of the most challenging issues with the use of LEDs is the
control of unwanted heat. The most common way to dissipate this
performance-hindering byproduct is to connect the LED package directly to a heat sink. To maximize the cooling performance
of the heatsink, Fujipoly offers its line soft Sarcon GR-ae thermal
interface materials.
The gel-like sheet compound is designed to efficiently transfer
heat from its source to the nearby heat sink. The physical properties of this material allow it to protect delicate board-level components as they fill unwanted air gaps and levels uneven surfaces.
This silicone based compound is available in nine thicknesses
that deliver a thermal conductivity of 1.3 W/m°K with a thermal
resistance as low as 0.50 °C cm2/W. Sarcon GR-ae is available in
pre-cut sheets up to 200 mm by 300 mm or die-cut to your exact
application specifications. In addition to growing LED lighting
applications, the same thermal interface material has proven successful in helping cool power control units, converters, inverters
and batteries.
20-1650 Silicone Potting and Encapsulating
Compound Can Withstand the Heat
20-1650, by Epoxies, Etc., is a
two component silicone elastomer
designed specifically for applications
where a large amount of heat is emitted such as high voltage assemblies.
Even for a silicone, which can operate under fairly high temperatures,
20-1650 outperforms. It operates in
environments from -65°C to 300°C (or up to 572° F).
The 20-1650 has been specially formulated for increased thermal stability. It is soft and flexible, and moves with components,
September/October 2013
www.ElectronicsProtectionMagazine.com
http://www.ElectronicsProtectionMagazine.com
Table of Contents for the Digital Edition of Electronics Protection - September/October 2013
Geist Unveils Rapid Deployment Data Center Environmental Monitoring System
Enabling Effective Thermal Management with DCIM
Predicting Gasket Performance: SE Measurements with a TEM Cell to Study Gasket Reliability
Rack Containment 101
The Nine Core Elements of DCIM
Using Electronic Locking Solutions to Secure Enclosures and Meet Storage Compliance Needs
Hammond’s HJ Series Ticks All the Boxes
Rogers Introduces Poron SlimGrip Foam
Ferrite Suppressors Clear Interference
Fujipoly Thermal Sheets are a Cooling Influence on LED Lighting
GE Introduces TLE Series UPS Platform
Gore PolyVent XL Improves Reliability of Large Outdoor Enclosures
IMI Sensors Launches Linear Adjust Mechanical Vibration Switch
Industry News
Calendar of Events
Five Ways to Realize Server Room Profitability
Electronics Protection - September/October 2013
https://www.nxtbook.com/nxtbooks/webcom/ep_2017summer
https://www.nxtbook.com/nxtbooks/webcom/ep_2017spring
https://www.nxtbook.com/nxtbooks/webcom/ep_2017winter
https://www.nxtbook.com/nxtbooks/webcom/ep_2016fall
https://www.nxtbook.com/nxtbooks/webcom/ep_2016summer
https://www.nxtbook.com/nxtbooks/webcom/ep_2016spring
https://www.nxtbook.com/nxtbooks/webcom/ep_2015winter
https://www.nxtbook.com/nxtbooks/webcom/ep_2015fall
https://www.nxtbook.com/nxtbooks/webcom/ep_2015summer
https://www.nxtbook.com/nxtbooks/webcom/ep_2015spring
https://www.nxtbook.com/nxtbooks/webcom/ep_2014winter
https://www.nxtbook.com/nxtbooks/webcom/ep_2014fall
https://www.nxtbook.com/nxtbooks/webcom/ep_2014summer
https://www.nxtbook.com/nxtbooks/webcom/ep_2014spring
https://www.nxtbook.com/nxtbooks/webcom/ep_20140102
https://www.nxtbook.com/nxtbooks/webcom/ep_20131112
https://www.nxtbook.com/nxtbooks/webcom/ep_20130910
https://www.nxtbook.com/nxtbooks/webcom/ep_20130708
https://www.nxtbook.com/nxtbooks/webcom/ep_20130506
https://www.nxtbook.com/nxtbooks/webcom/ep_20130304
https://www.nxtbook.com/nxtbooks/webcom/ep_20130102
https://www.nxtbook.com/nxtbooks/webcom/ep_20121112
https://www.nxtbook.com/nxtbooks/webcom/ep_20120910
https://www.nxtbook.com/nxtbooks/webcom/ep_20120607
https://www.nxtbook.com/nxtbooks/webcom/ep_20120304
https://www.nxtbook.com/nxtbooks/webcom/ep_20120102
https://www.nxtbook.com/nxtbooks/webcom/ep_20111112
https://www.nxtbook.com/nxtbooks/webcom/ep_20110910
https://www.nxtbook.com/nxtbooks/webcom/ep_20110607
https://www.nxtbookmedia.com